
Add to Cart
Minimally-Invasive PLDD Laser Surgery, 980nm Lumbar Laser
The Principle Of PLDD
In this procedure, laser energy is transmitted through a thin optical fiber into the disc. The aim of PLDD is to vaporize a small portion of the inner core. The ablation of a relatively small volume of the inner core results in an important reduction of intra-discal pressure, thus inducing reduction of disc herniation.
Percutaneous laser disc decompression (PLDD) is the utmost minimally invasive percutaneous laser techniquein the treatment of the disc hernias, cervical hernias, dorsal hernias(except for the segment T1-T5), and lumbar hernias. The procedureuses the laser energy to absorb the water within the herniated nucleuspulposus creating a decompression.
The PLDD treatment is performed on an outpatient basis using only local anesthesia. During the procedure, a thin needle is inserted into the herniated disc under x-ray or CT guidance. An optical fiber is inserted through the needle and laser energy is sent through the fiber, vaporizing a tiny portion of the disc nucleus. This creates a partial vacuum which draws the herniation away from the nerve root, thereby relieving the pain. The effect usually is immediate.
PLDD has proven to be safe and effective. It is minimally invasive, is performed in an outpatient setting, requires no general anesthesia, results in no scarring or spinal instability, reduces rehabilitation time, is repeatable, and does not preclude open surgery should that become necessary. It is an ideal choice for patients with poor results in non-surgical treatment.
- Portable design, only 2.1Kg
- Perfect heat management, no overheating
PLDD laser system is specially designed for PLDD mini-invasive surgery, providing a full set of high quality standard and optional accessories, such as puncture needle, Y-valve, optical fiber, safety goggles, footswitch, fiber cutter, carry case, cart and etc.
Specifications
Laser Type | GaAIAs Diode Laser |
Wavelength | 980nm |
Peak Power | 15w |
Operation Mode | CW, Single / Repeat Pulse |
Pulse Duration | 10us-3s |
Repetition Rate | 0.2Hz-50KHz |
Pilot Beam | Red Diode Laser of 650nm, Power<5mw |
Control Mode | High resolution 7inch Touch screen (600*1024px) |
Transmission System | Medical Fibers With SMA905 Connector |
Dimensions | 160(W)*180(L)*235(H) mm |
Weight | 2.1KG |
Benefits
Perfect tissue effect
Micro-invasive percutaneous access
The procedure is accompanied by minimal pain
The procedure can be performed under local anesthesia
No risk of scarring
Faster return to normal activity - in most cases the patient does not require a stay in a rehabilitation clinic